Quinn
Back

Total 92 courses

EPA 608 Certification Prep Core

Environmental Impact & Ozone Protection - EPA

Atmospheric Effects of Refrigerants

Atmospheric Effects of Refrigerants

Chlorine in CFC and HCFC Refrigerants

Chlorine in CFC and HCFC Refrigerants

EPA 608: Refrigerant Identification

EPA 608: Refrigerant Identification

CFC vs HCFC: Ozone Depletion Potential

CFC vs HCFC: Ozone Depletion Potential

Ozone Depletion and Refrigerant Impact

Ozone Depletion and Refrigerant Impact

Recovery & System Procedures - EPA

Refrigerant Cylinder Labeling Requirements

Refrigerant Cylinder Labeling Requirements

EPA 608: Refrigeration Gauges

EPA 608: Refrigeration Gauges

EPA 608: Refrigerant States and Pressures

EPA 608: Refrigerant States and Pressures

EPA 608 Leak Detection Compliance

EPA 608 Leak Detection Compliance

Refrigerant Separation: Zero Tolerance

Refrigerant Separation: Zero Tolerance

Refrigerant Management - EPA

Refrigerant Recycling for EPA 608

Refrigerant Recycling for EPA 608

EPA 608: Refrigerant Recovery

EPA 608: Refrigerant Recovery

EPA 608 Reclaim Requirements

EPA 608 Reclaim Requirements

Refrigerant-Lubricant Compatibility for EPA 608

Refrigerant-Lubricant Compatibility for EPA 608

EPA 608: Fractionation Problem

EPA 608: Fractionation Problem

Regulatory Framework - EPA

EPA 608: Venting Prohibition at Servicing

EPA 608: Venting Prohibition at Servicing

Venting Prohibition on Substitute Refrigerants

Venting Prohibition on Substitute Refrigerants

Venting Prohibition at Disposal

Venting Prohibition at Disposal

R-22 Phaseout: EPA 608 Exam Essentials

R-22 Phaseout: EPA 608 Exam Essentials

Montreal Protocol & EPA 608 Compliance

Montreal Protocol & EPA 608 Compliance

Safety Practices - EPA

Nitrogen Use: Pressure Regulation & EPA Compliance

Nitrogen Use: Pressure Regulation & EPA Compliance

Nitrogen Use for Leak Detection

Nitrogen Use for Leak Detection

Cylinder Fill Safety: The 80% Rule

Cylinder Fill Safety: The 80% Rule

Refrigerant Exposure Risks

Refrigerant Exposure Risks

Reusable vs Disposable Cylinders

Reusable vs Disposable Cylinders

Section 608 Compliance - EPA

EPA 608: The Sales Restriction

EPA 608: The Sales Restriction

Clean Air Act: Venting Prohibition

Clean Air Act: Venting Prohibition

AHRI 700-2016 Refrigerant Standard

AHRI 700-2016 Refrigerant Standard

Third-Party Equipment Certification

Third-Party Equipment Certification

EPA 608: Equipment Identification

EPA 608: Equipment Identification

Type 1 (Small Appliances)

Type I Recovery Methods & Safety - T1A

Refrigerant Decomposition Products

Refrigerant Decomposition Products

Refrigerant Identification: Pressure & Temperature

Refrigerant Identification: Pressure & Temperature

Solderless Access Fittings: EPA 608 Compliance

Solderless Access Fittings: EPA 608 Compliance

Operating Compressors with Passive Recovery Devices

Operating Compressors with Passive Recovery Devices

EPA 608: Access Valve Requirements

EPA 608: Access Valve Requirements

Type I Standards & Requirements - T1A

HFC-134a: EPA 608 Exam Prep

HFC-134a: EPA 608 Exam Prep

Pre-1993 Equipment: EPA Evacuation Rules

Pre-1993 Equipment: EPA Evacuation Rules

EPA 608: Evacuation Requirements (Post-1993)

EPA 608: Evacuation Requirements (Post-1993)

EPA 608 Type I: Small Appliance Definition

EPA 608 Type I: Small Appliance Definition

Type 2 (High-Pressure)

Type II Leak Detection & Repair - T2H

EPA 608: Leak Repair Recordkeeping

EPA 608: Leak Repair Recordkeeping

EPA 608: Leak Repair Extension Requirements

EPA 608: Leak Repair Extension Requirements

EPA 608: Commercial & Industrial Leak Rates

EPA 608: Commercial & Industrial Leak Rates

EPA 608: Allowable Leak Rates

EPA 608: Allowable Leak Rates

Signs of Leakage in High-Pressure Systems

Signs of Leakage in High-Pressure Systems

Type II Recovery Standards & Techniques - T2H

EPA 608: Liquid Recovery Speeds Up Process

EPA 608: Liquid Recovery Speeds Up Process

Speed Recovery Methods for EPA 608

Speed Recovery Methods for EPA 608

Vacuum Hold Requirements for EPA 608 Compliance

Vacuum Hold Requirements for EPA 608 Compliance

Methods for Reducing Cross-Contamination

Methods for Reducing Cross-Contamination

EPA 608: The 15-Pound Recovery Rule

EPA 608: The 15-Pound Recovery Rule

Type II Refrigeration Systems & Safety - T2H

Hermetic Compressors Under Vacuum

Hermetic Compressors Under Vacuum

Equipment Room Requirements: ASHRAE 15

Equipment Room Requirements: ASHRAE 15

Pressure-Temperature Relationships

Pressure-Temperature Relationships

Hydrocarbon Refrigerant Restrictions

Hydrocarbon Refrigerant Restrictions

EPA 608: Refrigerant Identification

EPA 608: Refrigerant Identification

Type 3 (Low-pressure)

Type III Leak Detection & Repair - T3L

EPA 608 Leak Rate Regulations

EPA 608 Leak Rate Regulations

EPA 608: Allowable Annual Leak Rates

EPA 608: Allowable Annual Leak Rates

Low-Pressure System Leak Detection

Low-Pressure System Leak Detection

EPA 608: Chronic Leak Reporting

EPA 608: Chronic Leak Reporting

EPA 608: Leak Test Pressurization

EPA 608: Leak Test Pressurization

Type III Recharging, Systems & Safety - T3L

R-123 Equipment Room Sensor Requirements

R-123 Equipment Room Sensor Requirements

Equipment Room Requirements: ASHRAE Standard 15

Equipment Room Requirements: ASHRAE Standard 15

Purpose of Purge Units in Low-Pressure Systems

Purpose of Purge Units in Low-Pressure Systems

Pressure-Temperature Relationships in Low-Pressure Systems

Pressure-Temperature Relationships in Low-Pressure Systems

EPA 608: Vapor Before Liquid Charging

EPA 608: Vapor Before Liquid Charging

Type III Recovery Standards & Techniques - T3L

Liquid Recovery in Low-Pressure Systems

Liquid Recovery in Low-Pressure Systems

EPA 608 Type III: Vapor Recovery Requirements

EPA 608 Type III: Vapor Recovery Requirements

Heating Oil to 130°F: EPA 608 Type III Requirement

Heating Oil to 130°F: EPA 608 Type III Requirement

Water Management in Low-Pressure Recovery

Water Management in Low-Pressure Recovery

High-Pressure Cut-Out Levels for Recovery Devices

High-Pressure Cut-Out Levels for Recovery Devices